Contact Us

If you still have questions and are an active SimuTech customer, please submit a request.

  • Ansys Training
  • Skills Center
  • Consulting
  • About
  • Contact Support
  • Home

  • Installation

      • Troubleshooting

          • Errors & Solutions

              • License Management

                  • Info

                      • Remote Solve Manager

                          • Employee Login

                          Can't find what you're looking for?

                          Contact Support

                          Installation & Licensing Center

                          • Home
                          • Installation
                            Installation Guides Installation Tasks Requirements & Info Optional Configurations Uninstallation
                          • Troubleshooting
                            Troubleshooting Guides License Manager Connectivity Issues License Checkout Issues Application Functionality Issues Windows OS / Hardware Issues CAD Plugin Issues Project Specific Issues Uninstallation Guides Diagnostic Resources & Logs Other Tasks
                          • Errors & Solutions
                            Behavior Based Issues & Solutions Error Messages & Solutions
                          • License Management
                            FlexNet Licensing Shared Web Licensing Elastic Licensing Licensing Portal Administration License Borrowing Reporting & Usage Stats Other
                          • Info
                          • Remote Solve Manager
                          + More

                          ERROR - An Unexpected Error (SIG$SEGV) Has Occurred

                          Authored by Caleb Scharf October 26th, 2026 11549 views 5 likes KB2202787

                          ERROR

                          Ansys Mechanical stops during a solve with a SIG$SEGV error like the one below. The error happens intermittently.

                          ***ERROR ***    CP =    64.031 TIME= 09:52:21
                          An unexpected error ( SIG$SEGV ) has occurred... ANSYS internal data 
                          has been corrupted. ANSYS is unable to recover and will terminate. 
                          Previously saved files are unaffected.  Please send the data leading
                          to this operation to your technical support provider, as this will allow ANSYS, Inc to improve the program.
                          
                          Current ANSYS Traceback: cdsfpr cdload loadhiswrite solvcl ANSYS

                          Software & Version

                          Ansys Mechanical 2021 R2

                          *This documented instance of this error occurred in this version but is not necessarily limited to this version.

                          Description/Cause

                          SIG$SEGV errors come from a problem between Ansys and the computer's software or hardware. Four separate problems can cause this error. They're listed in the order to rule them out, least disruptive first:

                          • Cause A - Corrupt model
                          • Cause B - Failing hardware, such as memory (RAM) or the hard drive
                          • Cause C - Corrupt Windows operating system
                          • Cause D - Corrupt Ansys installation

                          In this documented instance, the model solved on other computers and sometimes on the affected computer. That pointed away from the model and toward the computer itself. The cause was failing memory (RAM).

                          *The cause(s)/solution(s) we identified in this documented instance may not be the only cause(s)/solution(s) for this error.

                          Solution

                          Work through the solutions in order. Each one rules out one cause.

                          Solution to Cause A - Corrupt Model

                          1. Solve the model on another computer that has the same version of Ansys.
                          2. Check the result:
                            • If the model solves: the model isn't the cause. Continue to Solution to Cause B.
                            • If the model fails with the same SIG$SEGV error: the model is likely corrupt.

                          Solution to Cause B - Failing Hardware

                          1. If your computer is a Dell, run the built-in diagnostics: HOW TO - Run Dell Hardware Diagnostics.
                          2. Test your memory (RAM): How to Test Your Computer's RAM for Problems (howtogeek.com).
                          3. Check your hard drive's health: How to Check Your Hard Drive’s Health With CrystalDiskInfo (silicophilic.com).

                          Tell the reader what to do when a hardware test reports a fault. This instance was fixed by replacing failing memory.

                          Solution to Cause C - Corrupt Windows Installation

                          1. Check and repair Windows: Check & Repair Windows Installation Health.

                          Solution to Cause D - Corrupt Ansys Installation

                          1. Reinstall Ansys: Comprehensively Reinstall Ansys.

                          Verify the Fix Worked

                          1. After each solution, solve the model again on the affected computer.
                          2. If the solve finishes without the SIG$SEGV error, you're done. If the error comes back, continue with the next solution.

                          Was this helpful?

                          Yes
                          No

                          5 out of 16 found it helpful

                          Related Articles

                          ERROR - Ansys License Manager Won't Start

                          ERROR - Capability ANSYS IcePak does not exist in the ANSYS licensing pool.

                          ERROR - ANSYS Electronics Desktop Will Not Launch After Windows Update

                          ERROR - "Failed to Enable Feature" - Pro, Premium, Enterprise Licensing Available on Server

                          Popular Articles

                          Ansys Download & Installation Guide

                          INFO - Ansys Hardware Recommendations & Supported 3rd Party Software

                          HOW TO - Uninstall Ansys Software

                          HOW TO - Test & Fix FlexNet License Manager Connectivity Issues

                          HOW TO - Install an Ansys FlexNet License Key/File

                          Was this helpful?

                          Yes
                          No
                          Give feedback about this article

                          Can't find what you're looking for?

                          Contact Support

                          Recently Updated

                          • ERROR - The application requires the use of OpenGL version 4.3 (Ansys Mechanical)
                          • HOW TO - Install Ansys MCP Servers (VS Code & GitHub Copilot)
                          • HOW TO - Run Product & CAD Configuration Manager
                          • ERROR - Gather Diagnostic Information Fails with NoClassDefFoundError CountingOutputStream on Linux
                          • HOW TO - Download the Ansys Electronics Package (HFSS, Maxwell, Icepak, SIwave, Nuhertz)
                          • INFO - Ansys Hardware Recommendations & Supported 3rd Party Software
                          • HOW TO - Obtain Usage Data for Usage Reporting
                          • HOW TO - Fix Ansys Installation / Functionality Issues
                          • HOW TO - Edit the Windows Hosts File
                          • General Inquiries & Sales:
                          • (800) 566-9190
                          • Info@SimuTechGroup.com
                          • Contact Support
                          • Software
                          • Services
                          • Case Studies
                          • Ansys Training
                          • Consulting
                          • Technical Support
                          • About SimuTech
                          • Careers
                          • Privacy

                          © 2025 SimuTech Group


                          Knowledge Base Software powered by Helpjuice

                          Definition by Author

                          0
                          0
                          Expand NEW TAB

                          Hi there! 👋

                          How are you liking the Installation Center?

                          Terrible

                          Bad

                          OK

                          Good

                          Excellent

                          Feedback Successfully submitted