Contact Us

If you still have questions and are an active SimuTech customer, please submit a request.

  • Ansys Training
  • Skills Center
  • Consulting
  • About
  • Contact Support
  • Home

  • Installation

      • Troubleshooting

          • Errors & Solutions

              • License Management

                  • Info

                      • Remote Solve Manager

                          • Employee Login

                          Can't find what you're looking for?

                          Contact Support

                          Installation & Licensing Center

                          • Home
                          • Installation
                            Installation Guides Installation Tasks Requirements & Info Optional Configurations Uninstallation
                          • Troubleshooting
                            Troubleshooting Guides License Manager Connectivity Issues License Checkout Issues Application Functionality Issues Windows OS / Hardware Issues CAD Plugin Issues Project Specific Issues Uninstallation Guides Diagnostic Resources & Logs Other Tasks
                          • Errors & Solutions
                            Behavior Based Issues & Solutions Error Messages & Solutions
                          • License Management
                            FlexNet Licensing Shared Web Licensing Elastic Licensing Licensing Portal Administration License Borrowing Reporting & Usage Stats Other
                          • Info
                          • Remote Solve Manager
                          + More

                          ERROR - Access is Denied When Launching Fluent from Workbench on Remote Linux Nodes

                          Authored by Heribert Colombo October 28th, 2026 13 views 0 likes KB3999127

                          ERROR

                          When you launch Fluent from Ansys Workbench with Use Remote Linux Nodes enabled, Fluent fails to start Node 0 on the remote Linux system and shows the error below. You cannot run the simulation.

                          Connected License Server List: 1055@xxxxxxxx
                          Host spawning Node 0 on Machine "xxx.xxx.xxx.xx" (lnamd64).
                          Host waiting for connection from Node 0 at "xxx.xxx.xxx.xx:xxxxx"
                          
                          Access is Denied
                          
                          Check your network connections and remote shell configuration.
                          If you are on a slow network, running cache flush, or running through a scheduler like lsf or sge, you may choose to wait.
                          Type Crtl-C to interrupt.

                          Software & Version

                          Ansys Workbench and Fluent 2026 R1 (v261) on Windows.
                          *This documented instance of this error occurred in this version but is not necessarily limited to this version.

                          Description/Cause

                          You will usually also see:

                          • The same remote Linux node works when you launch from the Standalone Fluent Launcher on the same Windows computer.
                          • The same workflow works from Workbench 2025 R1.
                          • Workbench 2026 R1 may have worked before, then stopped.
                          • Licensing works: the license check succeeds and Ansys Licensing Settings shows no errors.
                          • SSH to the Linux node works from the command line. For example, Test-NetConnection <linux-node> -Port 22 returns TcpTestSucceeded : True.
                          • The failure happens on more than one Windows computer, so it points to the Workbench launch environment, not the network or firewall.

                          Workbench starts Fluent from the "Start in" folder of its shortcut. If that folder resolves to C:\WINDOWS\system32, the Fluent Launcher shows C:\WINDOWS\system32 as the Working Directory.

                          In 2026 R1, the cmd.exe process that runs the remote spawn command writes a temporary Message Passing Interface (MPI) output file (flmpi-<number>.txt) to the working directory. A Microsoft Sysinternals Process Monitor capture showed a cmd.exe command line similar to:

                          cmd.exe /c ssh -l <user> <linux-node> /<path>/v261/fluent/bin/fluent 3ddp -r26.1.0 -pdefault -node -t1 -mport <ip>:<ip>:<port>:0 > flmpi-<number>.txt 2>&1

                          A standard user does not have write permission to C:\WINDOWS\system32, so Windows denies the write and the remote node never starts. In the documented instance, the shortcut's "Start in" field was set to %HOMEDRIVE%%HOMEPATH%, which resolved to C:\WINDOWS\system32 instead of the user profile folder.

                          *The cause(s)/solution(s) we identified in this documented instance may not be the only cause(s)/solution(s) for this error.

                          Solution

                           

                          1. Check the Fluent Working Directory

                          1. Launch Fluent from Workbench 2026 R1, then select the Home tab of the Fluent Launcher.
                          2. Check the "Working Directory" field. If it shows C:\WINDOWS\system32, this cause applies, so continue to the next task. If it shows your user profile folder, this documented cause does not apply.

                            Note: In the Standalone Fluent Launcher, the same field shows the user profile folder, for example C:\Users\<username>. Replace <username> with your Windows username.

                           

                          2. Change the Workbench Shortcut "Start In" Folder

                          1. Close all Ansys applications.
                          2. Open the Start menu, right-click Workbench 2026 R1, and select Open file location.
                          3. Right-click the Workbench 2026 R1 shortcut and select Properties.
                          4. On the Shortcut tab, check the Start in field. If it is set to C:\Windows\System32 or %HOMEDRIVE%%HOMEPATH%, change it to a folder you can write to, such as your user profile folder: %USERPROFILE%
                          5. Click OK.

                            Note: If Windows asks for administrator permission, have your IT team make the change.

                           

                          If You Cannot Change the Shortcut

                          Give the user read and write permission to the folder used as the working directory. Do not do this for C:\Windows\System32; correct the working directory instead.

                           

                           

                          3. Verify the Fix Worked

                          1. Launch Workbench from the updated shortcut, then open Fluent on the remote Linux nodes again.
                          2. On the Home tab of the Fluent Launcher, check that "Working Directory" shows your user profile folder, for example C:\Users\<username>.
                          3. Check that Fluent starts on the remote nodes without the error in the ERROR section above. If it does, you're done.

                          Was this helpful?

                          Yes
                          No

                          0 out of 0 found it helpful

                          Related Articles

                          HOW TO - Grant Users Access to Ansys Cloud Burst Compute

                          INFO - Setting up a VPN to an Ansys License Server

                          Popular Articles

                          Ansys Download & Installation Guide (Start Here!)

                          INFO - Ansys Hardware Recommendations & Supported 3rd Party Software

                          HOW TO - Uninstall Ansys Software

                          HOW TO - Test & Fix FlexNet License Manager Connectivity Issues

                          HOW TO - Install an Ansys FlexNet License Key/File

                          Was this helpful?

                          Yes
                          No
                          Give feedback about this article

                          Can't find what you're looking for?

                          Contact Support

                          Recently Updated

                          • ERROR - Shared Web license shows 0 In use and 0 Available in Ansys Licensing Settings
                          • ERROR - Access is Denied When Launching Fluent from Workbench on Remote Linux Nodes
                          • HOW TO - Install the Ansys License Manager on Linux Without a GUI (Silent Install)
                          • HOW TO - Install or Uninstall Ansys Silently
                          • HOW TO - Uninstall Ansys Software
                          • ERROR - No Shared Web license found that enables feature aice_pak (Icepak Classic)
                          • HOW TO - Change or Rehost an Ansys FlexNet License Server
                          • HOW TO - Add FlexNet License Manager Support for Older Ansys Versions (2020 R2 & Prior)
                          • ERROR - An Unexpected Error (SIG$SEGV) Has Occurred
                          • General Inquiries & Sales:
                          • (800) 566-9190
                          • Info@SimuTechGroup.com
                          • Contact Support
                          • Software
                          • Services
                          • Case Studies
                          • Ansys Training
                          • Consulting
                          • Technical Support
                          • About SimuTech
                          • Careers
                          • Privacy

                          © 2025 SimuTech Group


                          Knowledge Base Software powered by Helpjuice

                          Definition by Author

                          0
                          0
                          Expand NEW TAB

                          Hi there! 👋

                          How are you liking the Installation Center?

                          Terrible

                          Bad

                          OK

                          Good

                          Excellent

                          Feedback Successfully submitted