ERROR
When upgrading the client software to a newer version of Ansys, in this case 2024R2, you receive an error when launching mechanical from workbench stating the version of the vendor daemon is too old. Older versions of Ansys work without error.
Version of vendor daemon is too old.
Feature: cfd_preppost
License path:1055@ServerName;
FlexNet Licensing error:-83,147
Software & Version
Mechanical 2024R2
*This example was taken from this version but is not necessarily limited to this version.
Description/Cause
Potential causes:
- The client software is running newer version of Ansys than the License Manager is. The License Manager version should always be the same or newer than any client software.
- The license file was manually modified to point to a custom location for the ansyslm.exe file and that file was outdated. Example:
SERVER SERVERNAME DISK_SERIAL_NUM=1234567890
VENDOR ansyslmd C:\SERVERNAME\IcePak\ansyslmd.exe
USE_SERVER
*The cause(s) we identified in this documented instance may not be the only cause(s) for this error.
Solution
Solution to Cause A
- This step must be performed on the computer hosting the License Manager.
- Download and Install the latest version of the License Manager.
Solution to Cause B
- This step must be performed on the computer hosting the License Manager.
- Stop the License Manager
- Open Notepad with Run As Administrator rights
- Click on File > Open then navigate to the ansyslmd.lic file in
C:\Program Files\ANSYS Inc\Shared Files\licensing\license_files
- Remove anything following “ansyslmd” in the VENDOR line.
- Save the file replacing the existing ansyslmd.lic file.
- Start the License Manager