Installation & Licensing Center
ERROR - Fluent Crashes Intermittently or Graphics Window Is Blank (HOOPS_PICTURE)
Authored by Carlos Rodriguez
October 25th, 2026
115 views
0 likes
KB3972514
ERROR
Fluent closes unexpectedly (aborts) at random points during a session on Windows. The crash is intermittent, so Fluent can run for several sessions without it happening.
After the graphics driver is changed to stop the crash, graphics windows (mesh, contours, plots) may open but stay solid gray, with nothing drawn.
If the graphics driver variable is misspelled, the Fluent console shows the following at startup and falls back to DirectX 11:
Graphics driver currently in use: dx11
Warning:
Specified graphics driver "opengi2" is not available on the current runtime environment.
Selected dx11 instead, the most appropriate driver for it.Software & Version
Fluent 2026 R1 on Windows 11.
*This documented instance of this error occurred in this version but is not necessarily limited to this version.
Description/Cause
Fluent can draw graphics with several drivers, and the best one depends on the computer's graphics card. The HOOPS_PICTURE system environment variable sets which driver Fluent uses.
On this computer, the crash was tied to the DirectX 11 (dx11) driver. Switching to opengl2 stopped the crash but left the graphics window blank. A software driver (opengl2-mesa or msw), which draws without using the graphics card, brought the display back.
*The cause(s)/solution(s) we identified in this documented instance may not be the only cause(s)/solution(s) for this error.
Solution
Before You Start
You need administrator rights on the computer to add a system environment variable.
1. Change the Graphics Driver
- Close all Ansys applications.
- Open the Windows Start menu, search for "Edit the system environment variables", and open it.
- Click Environment Variables.
- Under "System variables", click New, and enter these values:
| Setting | Value |
|---|---|
| Variable name | HOOPS_PICTURE |
| Variable value | opengl2 |
Check the Spelling
Type the value in lowercase. The character after "openg" is a lowercase L, not a capital I.
- Click OK in each window to save, then restart the computer.
2. Verify the Fix Worked
- Launch Fluent. If the console shows the warning in the ERROR section above, the value is misspelled. Correct it, restart, and check again.
- Load a case and display a mesh or contour. If it displays, you're done.
- If the graphics window stays solid gray, edit
HOOPS_PICTURE, change the value toopengl2-mesa, restart the computer, and test again.
Software Rendering Can Be Slower
opengl2-mesa and msw draw graphics without the graphics card, so the display can update more slowly on large models.
- If the display is still blank, change the value to
msw, restart the computer, and test again. - If none of these values restores the display, update the graphics card driver from the manufacturer's website. See ERROR - Cannot See Model in Graphics Area.